Innova Corporate (India) presents Antiscalant For High Silica Water (INNOVA MT 066), a premium-grade silica scale inhibitor engineered specifically for Reverse Osmosis (RO) systems operating with high silica concentrations. This specialized formulation effectively prevents the polymerization and stubborn deposition of silica on membrane surfaces, tackling one of the most challenging fouling issues in water treatment. By utilizing INNOVA MT 066, industrial facilities can significantly enhance recovery rates and protect critical assets from irreversible damage.
Our advanced INNOVA MT 066 technology is designed to extend membrane longevity and ensure uninterrupted operation, even when dealing with difficult or fluctuating feed water quality. This high-performance antiscalant reduces the need for frequent chemical cleanings and lowers operational risks, making it an essential solution for high-silica environments in industrial water treatment plants.
In calculating the dose rate of Tacelene Chem-7066, the membrane manufacturer's operating limits and feed water quality should be considered. All dose rate calculations should be made on the computer projection programme "e-WATER 5.0", which calculates the SCR for Silica.
Generally recommended dosage is 1 ppm in the feed water for every 6 to 7ppm of total silica in the feed water, depending on the operating pH and temperature.
At 25°C, pH 7 to 7.5 with 240mg/l silica in the concentrate. Tacelene Chem-7066 is normally dosed at 5.0 to 10 mg/L in the concentrate. Tacelene chem.-7066 can be diluted with product water and should be applied continuously by means of a suitable metering pump. Continuous feed and correct level of Tacelene Chem is essential since silica fouled membranes are difficult to Clean.
When both dissolved and colloidal silica is present, silica fouling can be difficult to predict because of the complexity of the silica reaction chemistry.
Preventing the formation of substrate material like insoluble calcium and iron salts is required in eliminating silica fouling. We recommend very effective auto flushing devices to applied with high silica waters.
Tacelene chem.-7066 has been developed specially as a SILICA inhibitor, for waters with SCR <1.3 to 4.2 mg/l.
For Ipb/Ksp ratios < 3 the preffered product of choice is Tacelene Chem-7065; for ratios 2.8 to 7.0, INNOVA MT 065 is normally dosed at 5.0 to 25 mg/L in the concentrate, which is equivalent to 2.5 to 6 mg/L in the feed water, dependent on the system recovery.
INNOVA MT 065 can be diluted with product water and should be applied continuously by means of a suitable metering pump. Continuous feed is essential since calcium sulphate is difficult to remove once precipitation has occurred.
Do not store the material in open, store in cool dark place away from direct sunlight. Keep the container tightly closed when not in use. This product exhibits very low order of oral toxicity. No special care is required in handling this product.