Manufacturers, Exporters and Suppliers of INNOVA BCD 501 – MBT Based Biocide for Corrosion Prevention & Microbial Control in Water Systems in Bawal

Biocides MBT Based (INNOVA BCD 501)
Biocides MBT Based (INNOVA BCD 501) in Bawal

Biocides MBT Based (INNOVA BCD 501) in Bawal

Innova Corporate (India) supplies MBT-based biocide (methylene bis-thiocyanate) for Bawal's anaerobic environments and closed systems – including closed-loop cooling systems, firewater storage tanks, and steel mill effluent channels. MBT is particularly effective against sulfate-reducing bacteria (SRB) and slime-forming organisms. For Bawal's steel re-rolling mills and metal casting foundries, where SRB activity in cooling loops and effluent channels produces hydrogen sulfide (rotten egg odor) and black sludge, MBT provides long-term control. It has the advantage of sustained activity (half-life 5-10 days) and thermal stability up to 60°C (140°F). Unlike glutaraldehyde, MBT has minimal odor and low volatility. For food processing plants (if any), MBT is used in pasteurizer cooling water at 10-25 ppm. It shows synergy with isothiazolines and DBNPA. However, MBT is not compatible with oxidizing biocides and may be deactivated by reducing agents. For severe SRB problems (black water, H₂S odor), we recommend a shock dose of 100-200 ppm MBT for 24-48 hours. MBT is available as a 20-30% active liquid and as solid (98-99% active) for slow-release applications. Storage: MBT may crystallize below 10°C (50°F) – Bawal's winter (Dec-Jan) can drop to 0-5°C, so store in a temperature-controlled area. Available in 25L and 200L drums (liquid) and 20kg bags (solid). We provide on-site SRB testing using API RP 38 culture bottles.

Advantages in Bawal:

  • It is a highly effective microbiocide tailored for Bawal's specific water mineralogy and microbial profiles.

Dosage :

    Dosage in cooling water treatment programs 25 to 45 ppm for effective control of biocide activity, for cooling waters.

Method of Feeding :

    INNOVA BCD 501can be fed as received or diluted with water minimum 10% concentration with any chemical feed solution. The chemical should be added to cooling tower basin (or any other point, which provides uniform mixing) addition should be made to metering pump to minimize handling.

Feed Requirements :

    Badly fouled systems must be cleaned before treatment to start. INITIAL DOSE - When the system is noticeably fouled, slug feed 25 to 50 ppm of INNOVA BCD 501 in the system. SUBSEQUENT DOSE - When the Microbial count is evident, slug feed 20 to 40 ppm of INNOVA BCD 501.

Control Testing :

    The best indication of the successful application of INNOVA BCD 501 is visual inspection of tower surfaces or monitoring changes in heat transfer on metal surface of process equipment.

    Uses of on-site bacterial counts or microscopic examination provide relative indicators of system cleanliness and biological control. If bacteria counts are used, Note that counts may be high immediately after biocide addition. Counts will be lower as control is achieved.

Packing :